JA-KNX Jablotron KNX interface

ELAUSYS JA-KNX is a KNX gateway for the Jablotron 100 alarm systems. It enables bidirectional communication with the alarm system using the RS485 communication module (JA-121T) from Jablotron.

Elausys JA-KNX - Jablotron KNX Interface
  • KNX Interface for Jablotron 100 alarm systems
  • Up to 32 bidirectional input/output (PG)
  • Real time status of each zone
  • Control up to 4 areas (arm/partial/disarm)
  • 9 status per area (intrusion, entry, exit, fire,…)
  • Recall of KNX scenes for each status
  • Power supply from the KNX bus
  • Integrated 12VDC output power supply (for JA-121T)
  • Built-in termination resistor for RS485
  • Communication fault monitoring

DESCRIPTION

The KNX interface module JA-KNX is a KNX gateway for the Jablotron 100 alarm systems. It enables bidirectional communication with the alarm system using the RS485 communication module (JA-121T) from Jablotron.

It allows integrators to take advantage of a fully integrated alarm system including KNX scenarios, automatic lighting using the motion detectors, arming or monitoring the system using a KNX visualization.

This interface is intended to be used with a JABLOTRON 100 series alarm system. The system must be equipped with a JA121T module for RS485 communication.

JA-KNX Jablotron Connection

CONNECTION

Elausys JA-KNX module is supplied from the KNX bus and provides the 12VDC power supply required by the J121T module.

 The RS485 bus must be interconnected between the JA121T and the JA-KNX interface using the blue screw terminals on both modules. The termination resistor is already integrated on the KNX interface module, therefore no additional component or wiring is required.

JA-KNX Jablotron JA121T wiring

SOFTWARE

Configuration of 16 or 32 PG are available and will be listed in the device group objects.

 Each PG of the Jablotron alarm system can be controlled by a Group object and its status is retrieved on a separate group object.

GO

NAME

DESCRIPTION

1

PGx

PG Control from KNX

2

PGx Status

PG status

The status of each zone from the Jablotron alarm system can be monitored by a Group object.

 

Each area can be controlled by using the 3 group objects: Arm, arm partially or disarm. Several statuses are available and have a dedicated group object. Up to 4 areas are listed in the group objects.

A scene can be assigned to each status. This scene number will be recalled each time the zone status is active (ON).

Each area has 12 Group Objects (GO), 3 for control  and 9 for the status to KNX.

GO

NAME

DESCRIPTION

185

Area x – Arm

Arm the Area

186

Area x – Stay arm

Stay arm the Area

187

Area x – Disarm

Disarm the Area

188

Area x – State disarmed

Area x status

189

Area x – Entry delay

Area x status

190

Area x – Exit delay

Area x status

191

Area x – State armed

Area x status

192

Area x – State partial armed

Area x status

193

Area x – Fire alarm

Area x status

194

Area x – Siren ON

Area x status

195

Area x – Panic alarm

Area x status

196

Area x – Intrusion alarm

Area x status

User manual & ETS Database

Version : 2.00

Release date : 19-FEB-2018

Applicable only to products delivered after the release date

Version : 1.01

Applicable only to products delivered until 19-FEB-2018