NXG-KNX Interlogix KNX interface – UltraSync

ELAUSYS NXG-KNX is a KNX gateway for the Interlogix UltraSync alarm systems (NetworXConnect, xGen, ZeroWire) from UTC Fire & Security. It enables bidirectional communication with the alarm system over Ethernet.

KNX Gateway for solar inverters
  • KNX Interface for Interlogix UltraSync alarm systems
  • Up to 96 zones status
  • Control up to 4 areas (arm/partial/disarm)
  • 9 status per area (alarm, entry, exit, fire,…)
  • Recall of KNX scenes for each status
  • Battery and AC Failure monitoring
  • Connected to the alarm system over Ethernet
  • Galvanic insulation from the KNX bus

DESCRIPTION

The KNX interface module NXG-KNX is a KNX gateway for the Interlogix alarm systems. It enables bidirectional communication with the alarm system over Ethernet.

It allows integrators to take advantage of a fully integrated alarm system including KNX scenarios, automatic lighting using the motion detectors, arming or monitoring the system using a KNX visualization.

KNX Interface Interlogix ultraSync

CONNECTION

An external power supply 12-30VDC is required and connected on the bottom side of the module, beside the RJ45 connector for the ethernet cable. The KNX bus is connected on the top side of the gateway.

INV-KNX gateway connection

SOFTWARE

Configuration of up to 96 zones are available and will be listed in the device group objects.

By default, zone status is configured for zone 1 to 96 of the alarm system. A general parameter allows to change for zone 97 to 192. Having then the possibility to use two gateways in the same installation to cover up to 192 zones of the alarm system.

Each ZONE has 1 Group Objects (GO) for the status to KNX. 

GO

NAME

DESCRIPTION

1

Zone x Status

Zone status

Up to 4 areas can be configured and listed in the group objects.

By default, areas are mapped to areas 1 to 4 of the alarm system but a parameter allows to change the area numbers to cover the areas 5 to 8 of the alarm system if needed.

Each area can be controlled by using the 3 group objects: Arm, Partial arm or disarm. Several statuses are available and have a dedicated group object.

A scene can be assigned to each status. This scene number will be recalled each time the area status is active (ON).

Each area has 12 Group Objects (GO), 3 for area control  and 9 for the area status to KNX.

GO

NAME

DESCRIPTION

185

Area x – Arm

Arm the Area

186

Area x – Partial arm

Partial arm the Area

187

Area x – Disarm

Disarm the Area

188

Area x – State disarmed

Area x status

189

Area x – Entry delay

Area x status

190

Area x – Exit delay

Area x status

191

Area x – State armed

Area x status

192

Area x – State partial armed

Area x status

193

Area x – Fire alarm

Area x status

194

Area x – Siren ON

Area x status

195

Area x – Panic alarm

Area x status

196

Area x – Intrusion alarm

Area x status

 

User manual & ETS Database

Version : 1.00

Release date : 22-DEC-2021

Applicable only to products delivered after the release date

WHERE TO BUY ?

This product is available on our web shop

 Customer feedback

Easy to program and install

Rated 5 out of 5
August 30, 2022

All products are easy in Programming and installation

IOANNIS MASTROKALOS, ELECTRICAL ENGINEER - ELEKTROMELETI AUDIO DESIGN

 Give us your feedback !