JA-KNX Jablotron KNX interface

ELAUSYS JA-KNX is a KNX gateway for the Jablotron 100 alarm systems. It enables bidirectional communication with the alarm system using the RS485 communication module (JA-121T) from Jablotron.

JA-KNX Jablotron KNX Interface
  • KNX Interface for Jablotron 100 alarm systems
  • Up to 32 bidirectional input/output (PG)
  • Control up to 4 zones (arm/partial/disarm)
  • 11 status per zone (intrusion, entry, exit, fire,…)
  • Recall of KNX scenes for each status
  • Power supply from the KNX bus
  • Integrated 12VDC output power supply (for JA-121T)
  • Built-in termination resistor for RS485
  • Communication fault monitoring

DESCRIPTION

The KNX interface module JA-KNX is a KNX gateway for the Jablotron 100 alarm systems. It enables bidirectional communication with the alarm system using the RS485 communication module (JA-121T) from Jablotron.

It allows integrators to take advantage of a fully integrated alarm system including KNX scenarios, automatic lighting using the motion detectors, arming or monitoring the system using a KNX visualization.

This interface is intended to be used with a JABLOTRON 100 series alarm system. The system must be equipped with a JA121T module for RS485 communication.

JA-KNX Jablotron Overview

CONNECTION

Elausys JA-KNX module is supplied from the KNX bus and provides the 12VDC power supply required by the J121T module.

 The RS485 bus must be interconnected between the JA121T and the JA-KNX interface using the blue screw terminals on both modules. The termination resistor is already integrated on the KNX interface module, therefore no additional component or wiring is required.

JA-KNX Connection

SOFTWARE

Configuration of 16 or 32 PG are available and will be listed in the device group objects.

 Each PG of the Jablotron alarm system can be controlled by a Group object and its status is retrieved on a separate group object.

GO

NAME

DESCRIPTION

1

PGx

PG Control from KNX

2

PGx Status

PG status

Up to 4 zones are listed in the group objects.

Each zone can be controlled by using the 3 group objects: Arm, arm partially or disarm. Several statuses are available and have a dedicated group object.

A scene can be assigned to each status. This scene number will be recalled each time the zone status is active (ON).

Each zone has 14 Group Objects (GO), 3 for zone control  and 11 for the zone status to KNX.

GO

NAME

DESCRIPTION

1

Zone x – Arm

Arm the zone

2

Zone x – Partial arm

Arm the zone partially

3

Zone x – Disarm

Disarm the zone

4

Zone x – Intrusion alarm

Zone x status

5

Zone x – Fire alarm

Zone x status

6

Zone x – External siren

Zone x status

7

Zone x – Internal siren

Zone x status

8

Zone x – Panic alarm

Zone x status

9

Zone x – Entry delay

Zone x status

10

Zone x – Exit delay

Zone x status

11

Zone x – State armed partially

Zone x status

12

Zone x – State armed

Zone x status

13

Zone x – State ready

Zone x status

14

Zone x – State disabled

Zone x status