NXG-KNX Interlogix KNX interface – UltraSync
ELAUSYS NXG-KNX is a KNX gateway for the Interlogix UltraSync alarm systems (NetworXConnect, xGen, ZeroWire) from UTC Fire & Security. It enables bidirectional communication with the alarm system over Ethernet.
- KNX Interface for Interlogix UltraSync alarm systems
- Up to 96 zones status
- Control up to 4 areas (arm/partial/disarm)
- 9 status per area (alarm, entry, exit, fire,…)
- Recall of KNX scenes for each status
- Battery and AC Failure monitoring
- Connected to the alarm system over Ethernet
- Galvanic insulation from the KNX bus
DESCRIPTION
The KNX interface module NXG-KNX is a KNX gateway for the Interlogix alarm systems. It enables bidirectional communication with the alarm system over Ethernet.
It allows integrators to take advantage of a fully integrated alarm system including KNX scenarios, automatic lighting using the motion detectors, arming or monitoring the system using a KNX visualization.
CONNECTION
An external power supply 12-30VDC is required and connected on the bottom side of the module, beside the RJ45 connector for the ethernet cable. The KNX bus is connected on the top side of the gateway.
SOFTWARE
Configuration of up to 96 zones are available and will be listed in the device group objects.
By default, zone status is configured for zone 1 to 96 of the alarm system. A general parameter allows to change for zone 97 to 192. Having then the possibility to use two gateways in the same installation to cover up to 192 zones of the alarm system.
Each ZONE has 1 Group Objects (GO) for the status to KNX.
GO |
NAME |
DESCRIPTION |
1 |
Zone x Status |
Zone status |
Up to 4 areas can be configured and listed in the group objects.
By default, areas are mapped to areas 1 to 4 of the alarm system but a parameter allows to change the area numbers to cover the areas 5 to 8 of the alarm system if needed.
Each area can be controlled by using the 3 group objects: Arm, Partial arm or disarm. Several statuses are available and have a dedicated group object.
A scene can be assigned to each status. This scene number will be recalled each time the area status is active (ON).
Each area has 12 Group Objects (GO), 3 for area control and 9 for the area status to KNX.
GO |
NAME |
DESCRIPTION |
185 |
Area x – Arm |
Arm the Area |
186 |
Area x – Partial arm |
Partial arm the Area |
187 |
Area x – Disarm |
Disarm the Area |
188 |
Area x – State disarmed |
Area x status |
189 |
Area x – Entry delay |
Area x status |
190 |
Area x – Exit delay |
Area x status |
191 |
Area x – State armed |
Area x status |
192 |
Area x – State partial armed |
Area x status |
193 |
Area x – Fire alarm |
Area x status |
194 |
Area x – Siren ON |
Area x status |
195 |
Area x – Panic alarm |
Area x status |
196 |
Area x – Intrusion alarm |
Area x status |
User manual & ETS Database
Version : 1.00
Release date : 22-DEC-2021
Applicable only to products delivered after the release date
Customer feedback
Easy to program and install
All products are easy in Programming and installation